Diagnostic Acute Myeloid Leukemia panel

Alphabetical Test listing

Diagnostic Acute Myeloid Leukemia panel-12420

  
Diagnostic Acute Myeloid Leukemia panel
  
12420
  
LAB12420
  
PATR
  
Acute Leukemia
AML
B-ALL
Blast
Leukemia panel
Leukemia/Lymphoma panel
Precursor
T- ALL
  

Determination of blast cell phenotype

  

Pathology orders only

  
EDTA whole blood
  
  
4.0 mL
  
3.0 mL
  
 
  • Submit whole blood specimen in lavender (EDTA) tube
  • Do not spin
  

Whole blood:

Lavender (EDTA), 4mL

 

 

 

  
Body fluid
Bone marrow
Spinal fluid
Tissue
  
Varies; see Alternate collection instructions
  

Body fluid

  • Collect 20 mL (minimum 5 mL) of body fluid and place in a Falcon vial/tube - 15mL
    • Do not add anticoagulant or holding media
    • The volume required is dependent upon the white blood cell (WBC) count. Smaller volumes are sufficient if the cell count is high

Bone marrow

  • Collect 3 mL (minimum 1 mL) in a sodium heparinized (Na hep) syringe
    • Specimens collected in EDTA are acceptable, but not preferred
  • Transfer to an anticoagulant free sterile tube
  • If unable to collect a bone marrow aspirate, a bone marrow core placed in RPMI with Hepes, Pen Strep and FBS is acceptable

Spinal fluid

  • Collect 5 mL (minimum 1 mL) in a sterile vial/container.
    • Do NOT add any anticoagulant or holding media
    • The volume required is dependent upon the white blood cell (WBC) count. Smaller volumes are sufficient if the cell count is high

Tissue

  • Immediately following collection, place the fine needle aspirate (FNA) or tissue in RPMI with Hepes/Pen strep/FBS -15 mL
  

Body fluid

Falcon vial/tube - 15mL

 

Bone marrow

Bone marrow transport vial/tube

 

Spinal fluid

Sterile vial/container

 

Tissue

RPMI with Hepes/Pen strep/FBS -15 mL

  
  • Complete the "Brief clinical information" and "What do you want answered by Flow?" areas on the request form.
  

EDTA whole blood

Ambient

Body fluid

Refrigerated

Bone marrow

Ambient

Spinal fluid

Refrigerated

Tissue

Refrigerated

  
  • Improper label (unlabeled or mislabeled)
  • Wrong container (anticoagulant or solution)
    • Tissues submitted in saline or B5 fixative are not acceptable and will be rejcted
  • Improper blood/anticoagulant ratio
  • Delay in transport
  • Improper storage
  • Inappropriate timing of collection
  • Interfering substances
  • Leaking container
  
AHL - Flow Cytometry: F
  
Mo - Fr
  
2 days
  

Flow cytometry

  

Tubes and Markers:

Tubes:
M1, M2, M3, M4, M5

Markers:CD2, CD3(cy), CD5, CD7, CD10, CD11b, CD13, CD14, CD15, CD16, CD19, CD22(cy), CD33, CD34, CD36, CD38, CD45, CD45RA, CD56, CD64, CD65, CD71, CD79a(cy), CD117, CD123, CD235a, CD300e, CD371, HLA-DR, MPO(cy), TdT(n)

  
88184
88185 x 30
  
06/12/2017
  
10/28/2022
  
01/09/2024