Chlamydia trachomatis & Neisseria gonorrhoeae, amplified probe-6746

Test info

  
Chlamydia trachomatis & Neisseria gonorrhoeae, amplified probe
  
6746
  
LAB6746
  
GCC
  
Chlamydia trachomatis
gonorrheae
Neisseria gonorrhoeae

Specimen

  

Male urethral swab specimens:

  • Patient should not have urinated for at least 1 hour prior to specimen collection.

Male and female urine specimens:

  • Patient should not have urinated for at least 1hr prior to specimen collection.
  • Female patients should not cleanse labial area prior to providing the specimen.
  
Swab:
Endocervical, oral /mouth, rectal, vaginal or male urethral
  

Aptima Unisex swab kit

Female endocervical or male urethral sample collections

 

Aptima Multitest swab transport media

Oral/mouth, rectal or vaginal sample collections

 

 

  

The following instructions are provided on the kit packages.

Female endocervical swab specimens:

Use Aptima Unisex swab collection kit.

  1. Remove excess mucus from cervical os and surrounding mucosa using cleaning swab (white shaft swab in package with red printing). Discard the white swab.
  2. Insert specimen collection swab (blue shaft swab in package with green printing) into endocervical canal.
  3. Gently rotate swab clockwise for 10 to 30 seconds in endocervical canal to ensure adequate sampling.
  4. Withdraw swab carefully; avoid any contact with vaginal mucosa.
  5. Remove the cap from swab specimen transport tube and immediately place specimen collection swab into specimen transport tube.
  6. Carefully break swab shaft at score line and discard the top portion of the swab shaft; use care to avoid splashing contents.
  7. Tightly re-cap the specimen transport tube tightly.

Female vaginal specimens

Option when a pelvic exam is not otherwise indicated for clinician or patient-collected specimen. Not for home use. Patient collection is limited to health care facilities where support/counseling is available to explain procedures and precautions.

Use Aptima Multitest swab collection kit

  1. Partially peel open the swab package and remove the swab. Do not touch the soft tip or lay the swab down. If the soft tip is touched, the swab is laid down, or the swab is dropped, use a new collection kit.
  2. Hold the swab, placing your thumb and forefinger in the middle of the swab shaft covering the score line. Do not hold the swab shaft below the score line.
  3. Carefully insert the swab into the vagina about 2 inches past the introitus and gently rotate the swab for 10 to 30 seconds. Make sure the swab touches the walls of the vagina so that moisture is absorbed by the swab and then withdraw the swab without touching the skin.
  4. While holding the swab in the same hand, unscrew the cap from the tube, taking care not to spill the contents of the tube. If the contents of the tube are spilled, use a new collection kit.
  5. Immediately place the swab into the transport tube so that the score line is at the top of the tube.
  6. Carefully break the swab shaft at the score line against the side of the tube.
  7. Immediately discard the top portion of the swab shaft.
  8. Tightly screw the cap onto the tube.

Male urethral swab specimens:

  1. Insert specimen collection swab (blue shaft swab in package with green printing) 2 to 4 cm into urethra.
  2. Gently rotate swab clockwise for 2 to 3 seconds in urethra to ensure adequate sampling and carefully withdraw the swab.
  3. Remove cap from swab specimen transport tube and immediately place specimen collection swab into specimen transport tube.
  4. Carefully break swab shaft at score line and discard the top portion of the swab shaft; use care to avoid splashing contents.
  5. Tightly screw the cap onto the tube.

Rectal swab specimens:

Use Aptima Multitest swab collection kit

  1. Partially peel open the swab package. Remove the swab. Do not touch the soft tip or lay the swab down. If the soft tip is touched, the swab is laid down, or the swab is dropped, use a new collection kit.
  2. Hold the swab, placing your thumb and forefinger in the middle of the swab shaft covering the score line. Do not hold the swab shaft below the score line.
  3. Carefully insert the swab into the rectum about 1-2 inches (3-5 cm) past the anal margin and gently rotate the swab for 5 to 10 seconds. Withdraw the swab without touching the skin.
  4. While holding the swab in the same hand, unscrew the cap from the tube, taking care to not spill the contents of the tube. If the contents of the tube are spilled, use a new collection kit.
  5. Immediately place the swab into the transport tube so that the score line is at the top of the tube.
  6. Carefully break the swab shaft at the score line against the side of the tube.
  7. Immediately discard the top portion of the swab shaft.
  8. Tightly screw the cap onto the tube.

Oral swab specimens:

Use Aptima Multitest swab collection kit

  1. Partially peel open the swab package. Remove the swab. Do not touch the soft tip or lay the swab down. If the soft tip is touched, the swab is laid down, or the swab is dropped, use a new collection kit.
  2. Hold the swab, placing your thumb and forefinger in the middle of the swab shaft covering the score line. Do not hold the swab shaft below the score line.
  3. Carefully insert the swab into the throat ensuring contact with bilateral tonsils (if present) and the posterior pharyngeal wall, then withdraw the swab without touching the inside of the cheeks or tongue.
  4. While holding the swab in the same hand, unscrew the cap from the tube, taking care not to spill the contents of the tube. If the contents of the tube are spilled, use a new collection kit.
  5. Immediately place the swab into the transport tube so that the score line is at the top of the tube.
  6. Carefully break the swab shaft at the score line against the side of the tube.
  7. Immediately discard the top portion of the swab shaft.
  8. Tightly screw the cap onto the tube.

 

  

Aptima Unisex swab kit

Female endocervical or male urethral samples

Aptima Multitest swab transport media

Oral/mouth, rectal or vaginal samples

 

  
Urine, voided
  

Screw cap plastic container (sterile) 

Urine sample collection

  

Male and female urine specimens:

  1. Direct patient to provide first-catch urine (approximately 20 to 30mL of initial urine stream) into urine collection cup free of any preservatives.
    • The cup should be removed from the urine stream when 20-30 mL of urine is in the cup. Collection of larger volumes of urine may result in specimen dilution that may reduce test sensitivity and should not be sent for testing.
  

Urine specimens must be transferred to an Aptima specimen transport tube by the collecting site, within 24 hours of collection, and prior to specimen transport.

  1. Remove cap from urine specimen transport tube and transfer 2mL of urine into urine specimen transport tube using disposable pipette provided. The correct volume of urine has been added when fluid level is between black fill lines on urine specimen transport tube label.
  2. If refrigerated, urine may be transferred to the transport tube at the collection site within 24 hours.
  3. Tightly screw the cap onto the tube.
  
  

Swab:

Ambient (preferred) - 60 days

Refrigerated - 60 days

Frozen - NO

Urine:

Ambient (preferred) - 30 days

Refrigerated - 30 days

Frozen - NO

 

  
1 week
  
  • Improper label (unlabeled or mislabeled)
  • Sources other than female endocervical, oral, rectal, vaginal, male urethral or voided urine
  • Leaking container
  • No swab, white swab, or two swabs in Aptima swab transport tube
  • Swab not from Aptima Unisex swab collection kit
  • Pink-shafted swab for cervical, endocervical, or urethral source
  • Blue-shafted swab for vaginal, oral or rectal source
  • Collection from vaginal cuff source
  • Midstream or Clean Catch Urine.
  • Urine collected for chemistry testing or cultures cannot be used for GC or Chlamydia PCR testing
  • Urine transport tube not filled to “Fill area” (above or below – rejected)
  • Urine not in Aptima transport tube
    • Client may transfer urine to transport tube within 24 hr. of collection.
    • Due to nucleic acid cross-contamination issues, this must be done at the client site and will not be done at Allina Health Laboratory.
    • If the urine has not been opened in the lab, it may be returned to the client to be transferred to the transport tube; otherwise, recollect.)
  • Frozen specimens

 

Performance

  
AHL - Microbiology: M
  
Daily
  
1 - 3 days
  

Target Capture with Transcription-Mediated Amplification

Clinical and Interpretive info

  

Negative

  

 

Chlamydia trachomatis probe versus patient infected status

Neisseria gonorrhoeae probe versus patient infected status

Specimen

Sensitivity (%)

Specificity (%)

Sensitivity (%)

Specificity (%)

Female endocervical swab

94.2

97.6

99.2

98.7

Female urine

94.7

98.9

91.3

99.3

Female vaginal swab

97.2

94.9

97.3

99.2

Male urethral swab

95.9

97.5

99.1

97.8

Male urine

97.9

98.5

98.5

99.6

Overall

95.9

98.2

97.8

98.9

Billing

  
87491
87591
  
Yes
  

Tracking

  
09/08/2005
  
12/26/2023
  
12/18/2023