Acarus mite, IgE-994

Test info

  
Acarus mite, IgE
  
994
  
LAB994
  
MSO
  
Allergen
Acarus Siro, dust mite
Flour mite
Grain mite
Storage dust mite, Acarus siro
  

Detect possible allergic responses to various substances in the environment such as animals, antibiotics, foods, grasses, house dust, mites, insects, insulin, molds, smuts, trees, and weeds; evaluate hay fever, asthma, atopic eczema, and respiratory allergy.

Specimen

  
Serum
  
  
1.0 mL
  
0.2 mL
  

Immediatley following collection, mix sample by gently inverting 5 times

  
  1. Allow sample to clot for a minimum of 30 minutes
  2. Spin
  

Gold serum separator (SST) tube

  
  
  1. Allow sample to clot
  2. Spin
  3. Transfer 1.0mL of serum to a Transfer vial/tube with cap - 12mL (LabCorp) labelled as "serum"
  
  

Ambient (preferred) - 14 days

Refrigerated - 14 days

Frozen - 3 months

  

Lipemic samples may lead to rejection

Performance

  
LabCorp Burlington (602677): R-NX
  
Daily
  
3 - 4 days
  

ImmunoCap

Clinical and Interpretive info

  

Level of Specific IgE

Class

Description of Class

< 0.10

0

Negative

0.10 - 0.31

0/I

Equivocal / Low

0.32 - 0.55

I

Low

0.56 - 1.40

II

Moderate

1.41 - 3.90

III

High

3.91 - 19.00

IV

Very High

19.01 -100.00

V

Very High

> 100.00

VI

Very High

Billing

  
86003
  
Yes
  

Tracking

  
01/28/2020
  
01/27/2021
  
11/24/2023