Poliovirus (types 1, 3) antibodies-994

Test info

  
Poliovirus (types 1, 3) antibodies
  
994
  
LAB994
  
MSO
  
Enterovirus; Poliovirus (1,3) Abs Poliovirus (Types 1,3) Abs
Poliovirus (Types 1,3) Antibodies
Poliovirus 1, 3 Antibody (Immune Status)
Poliovirus Antibodies
Poliovirus Antibody, Neutralization
  

Detect neutralizing antibodies to poliovirus (types 1 and 3). 

Specimen

  
Serum
  
  
1.0 mL
  
0.2 mL
  

Immediately following collection, thoroughly mix sample by gently inverting 5 times

  
  1. Allow sample to clot for a minimum of 30 minutes
  2. Spin within two (2) hours of sample collection
  

Gold serum separator (SST) tube

  
  
  1. Allow sample to clot
  2. Spin within two (2) hours of sample collection
  3. Transfer serum to a Transfer vial/tube with cap - 12mL (LabCorp), labelled as serum
  
  

Refrigerated (preferred) -  2 weeks 

Ambient – 48 hours

Frozen – 1 year

  
  • Plasma.
  • Contaminated specimen
  • Hemolysis
  • Severe lipemia

Performance

  
ARUP (2014107) via LabCorp (009985): R-NX
  
Mo - Fr
  
6-12 days
  

Semi-quantitative serum neutralization

Clinical and Interpretive info

  

< 1:10 

No detectable poliovirus antibodies.

≥ 1:10 

Antibody to poliovirus detected, which may represent prior immunization or current or past infection.

  

The presence of neutralizing antibodies against poliovirus implies immunity. The serum neutralization test is serotype specific. Antibodies against one type does not indicate immunity against the other type.

Billing

  
86658 x 2

Tracking

  
04/14/2021
  
12/18/2023
  