Hydroxychloroquine, serum/plasma-994

Test info

  
Hydroxychloroquine, serum/plasma
  
994
  
LAB994
  
MSO
  
Plaquenil
  
  • This test is used to demonstrate the presence of drug to rule out patient non-compliance or to assess acute toxicity or overdose
  • This test may also be useful in establishing a target range for HCQ use in prophylaxis or treatment of infection

Specimen

  
Serum
  
  
1.0 mL
  
0.4 mL
  

Immediately following collection, thoroughly mix sample by gently inverting 5 times

  
  1. Allow sample to clot for a minimum of 30 minutes
  2. Spin within two (2) hours of sample collection
  

Gold serum separator (SST) tube

  
EDTA plasma
Heparin plasma
  

Red serum vial/tube, 5 mL

Lavender (EDTA), 4mL

Dk green heparin (Li or Na), no gel

 

  

Lavender/Dk green:

Immediately following collection, mix sample thoroughly by gently inverting 8 - 10, times to prevent clotting

  

Red:

  1. Allow sample to clot
  2. Spin
  3. Transfer serum to a Transfer vial/tube with cap - 12mL (LabCorp), labelled as serum, within two (2) hours of sample collection

Lavender/Dk green:

  1. Spin
  2. Transfer plasma to a Transfer vial/tube with cap - 12mL (LabCorp), labelled as the appropriate plasma type, within two (2) hours of sample collection
  
  

Ambient (preferred) - 17 days

Refrigerated - 17 days

Frozen - 23 days

    Freeze/thaw cycles, stable x6

  
  • Gross hemolysis

Performance

  
LabCorp Burlington (504810): R-NX
  
Th
  
7 days
  

High Performance Liquid Chromatography/Tandem Mass Spectrometry (LC-MS/MS)

Clinical and Interpretive info

  

An interpretive report will be provided

Billing

  
80220
  
Result SOLOINC

Tracking

  
05/29/2019
  
01/03/2022