Tacrolimus-2439

Test info

  
Tacrolimus
  
2439
  
80197.0
  
F50
  
FK - 506
FK506:ProGraf
  

Biotin supplements may cause clinically significant interference for this test assay. If interference is suspected, it is strongly recomended that biotin is discontinued for at least one week prior to retesting

Specimen

  
EDTA whole blood
  
  
2.0 mL
  
0.4 mL
  

Immediatley following collection, mix sample thoroughly by gently inverting 8 - 10, times to prevent clotting

  

Lavender (EDTA), 4mL

  

Refrigerated (preferred) - 7 days

Ambient - 5 days

Frozen - 3 months

  
  • Improper labels (unlabeled or mislabeled)
  • Improper anticoagulant or ratio
  • Delay in transport
  • Improper storage temperature affecting results
  • Improper container
  • Leaking container resulting in compromised specimen
  • Quantity not sufficient (QNS)

Performance

  
AHL - Chemistry: C
  
Daily
  
1 day
  

Electrochemiluminescence immunoassay (ECLIA)

Clinical and Interpretive info

  

Target blood levels in heart transplant recipients (ng/mL):

0 – 3 months post transplant 12 – 15
3 - 6 months post transplant: 10 - 15
6 - 12 months post transplant: 8 - 12
>12 months post transplant: 5 - 10

Target blood levels in kidney transplant recipients (ng/mL):

0 - 3 months post transplant: 10 - 12
>3 - 6 months post transplant: 8 - 10
>6 - 12 months post transplant: 5 - 8
>12 months post transplant: 4 - 6

Patients may have an individual goal range due to risk of rejection, or adverse effects of tacrolimus