Egg white (F1), IgE-4205

Test info

  
Egg white (F1), IgE
  
4205
  
86003.27
  
F1
  
Allergen
ImmunoCap
R13
  

Intended for diagnostic use as an aid in the clinical diagnosis of IgE mediated allergic disorders in conjunction with other clinical findings.

Specimen

  
Serum
  
  
1.0 mL
  
0.5 mL
  
  • For more than one allergen, use this formula to calculate the amount of serum required:

50 µL X (# of allergens) + 250 µL = Total amount serum needed

  • Immediately following collection, thoroughly mix sample by gently inverting 5 times
  
  1. Allow sample to clot for a minimum of 30 minutes
  2. Spin within two (2) hours of sample collection
  

Gold serum separator (SST) tube

  

Red serum vial/tube - 5 mL

Red/grey serum separator (SST) vial/tube, 10 mL

  
  1. Allow sample to clot
  2. Spin
  3. Transfer serum to a False bottom plasma/serum transport vial/tube (AHL), labelled as serum, within two (2) hours of sample collection 
  

False bottom plasma/serum transport vial/tube (AHL)

Red/grey serum separator (SST) vial/tube, 10 mL

  

Ambient (preferred) - 3 days

Refrigerated - 7 days

Frozen (OK, one time)

  
  • Improper labels (unlabeled or mislabeled)
  • Hemolysis (some procedures)
  • Improper anticoagulant or ratio
  • Delay in transport
  • Improper storage temperature affecting results
  • Improper container
  • Leaking container resulting in compromised specimen
  • Quantity not sufficient (QNS)

Performance

  
AHL - Immunology: I-L
  
Mo - Fr
  
3 - 5 days
  

Fluorescence Enzyme Immunoassay (FEIA)

Clinical and Interpretive info

  

< 0.35 kU/L

  

Allergy class severity values

ImmunoCAP IGE Class Reference Values:

Traditionally, allergen tests have been reported with an associated class value of zero to 6, with Class 0 indicating an undetectable allergen level, and Class 6 indicating a strong positive allergen level.

The following chart correlates ImmunoCAP IgE allergen results in kU/L to the associated class, with a suggested interpretation. This chart is applicable to all allergen-specific tests at Allina Health Laboratory, which are performed exclusively on ImmunoCAP assays. Note that the Class Reference Values provided are specific for ImmunoCAP assays and may not be used to interpret allergy tests performed by other (non-ImmunoCAP) methods.

 

 Class  IgE kU/L  Interpretation
0  <0.35  Undetectable
1  0.35 - 0.70  Equivocal
2  0.71 - 3.50  Positive
3  3.51 - 17.50  Positive
4  17.51 - 50.00  Strong positive
5  50.01 - 100.00  Strong positive
6  >100.00  Strong positive