Fibroblast growth factor 23

Alphabetical Test listing

Fibroblast growth factor 23-994

  
Fibroblast growth factor 23
  
994
  
LAB994
  
FGF-23
  
FGF-23
FGF-23 C-Terminal Fragment
  

Measurement of Fibroblast Growth Factor 23 in plasma

  

This test was developed, and its performance characteristics determined by LabCorp. It has not been cleared or approved by the Food and Drug Administration.

  

A morning 12-hour fasting sample is recommended but not required.

  
EDTA plasma
  
  
1 mL
  
0.3 mL (Note: This volume does not allow for repeat testing)
  

Immediately following collection, mix sample thoroughly by gently inverting 8 - 10, times to prevent clotting.

  
  1. Centrifuge specimen within one (1) hour of collection
  2. Transfer plasma to a Screw-cap polypropylene frozen transport vial/tube - 4mL (LabCorp), labelled as EDTA plasma
  3. Refrigerate
  

Refrigerated (preferred) – 14 days

Ambient - 16 hours

Frozen - 14 days

  
  • Gross lipemia
  • Non-plasma sample received
  • Plasma sample received that is not EDTA
  
LabCorp (004380): R-LC
  
Fri
  
4 - 10 days
  

Enzyme-linked immunosorbent assay (ELISA).  This test is a second-generation C-terminal assay that measures both the intact FGF-23 and its C-terminal fragments.

  

44 – 215   RU/mL

  
 
  
83520
  

46699-5

  
05/29/2019
  
02/02/2023