Manganese, Serum/Plasma

Alphabetical Test listing

Manganese, Serum/Plasma-994

  
Manganese, Serum/Plasma
  
994
  
LAB994
  
MSO
  
Metal free serum
  
  
2.0 mL
  
0.6 mL
  

Immediately following collection, mix sample thoroughly by gentle inverting 8 - 10 times to prevent clotting

  
  1. Allow specimen to clot
  2. Spin and carefully transfer serum or plasma into a Metal free transfer vial/tube, labelled as serum, within two (2) hours of sample collection
  
  
EDTA plasma, metal free
  
  

Immediately following collection, mix sample thoroughly by gentle inverting 8 - 10 times to prevent clotting

  

Refrigerated (preferred) - 30 days

Ambient - 30 days

Frozen - 30 days

  
NMS (2570SP) via LabCorp (834160); R-NX
  
7 days
  

Inductively Coupled Plasma/Mass Spectrometry (ICP/MS)

  

0.7 - 2.0 mcg/L

  
83785
  
03/25/2025
  
03/25/2025