Diagnostic Acute Myeloid Leukemia panel

Alphabetical Test listing

Diagnostic Acute Myeloid Leukemia panel-12420

  
Diagnostic Acute Myeloid Leukemia panel
  
12420
  
LAB12420
  
PATR
  
Acute Leukemia
AML
B-ALL
Blast
Leukemia panel
Leukemia/Lymphoma panel
Precursor
T- ALL
  

Determination of blast cell phenotype

  

Pathology orders only

  
EDTA whole blood
  
  
4.0 mL
  
3.0 mL
  
 
  • Submit whole blood specimen in lavender (EDTA) tube
  • Do not spin
  

Whole blood:

Lavender (EDTA), 4mL

 

 

 

  
Body fluid
Bone marrow
Spinal fluid
Tissue
  
Varies; see Alternate collection instructions
  

Body fluid

  • Collect 20 mL (minimum 5 mL) of body fluid and place in a Falcon vial/tube - 15mL
    • Do not add anticoagulant or holding media
    • The volume required is dependent upon the white blood cell (WBC) count. Smaller volumes are sufficient if the cell count is high

Bone marrow

  • Collect 3 mL (minimum 1 mL) in a sodium heparinized (Na hep) syringe
    • Specimens collected in EDTA are acceptable, but not preferred
  • Transfer to an anticoagulant free sterile tube
  • If unable to collect a bone marrow aspirate, a bone marrow core placed in RPMI with Hepes, Pen Strep and FBS is acceptable

Spinal fluid

  • Collect 5 mL (minimum 1 mL) in a sterile vial/container.
    • Do NOT add any anticoagulant or holding media
    • The volume required is dependent upon the white blood cell (WBC) count. Smaller volumes are sufficient if the cell count is high

Tissue

  • Immediately following collection, place the fine needle aspirate (FNA) or tissue in RPMI with Hepes/Pen strep/FBS -15 mL
  

Body fluid

Falcon vial/tube - 15mL

 

Bone marrow

Bone marrow transport vial/tube

 

Spinal fluid

Sterile vial/container

 

Tissue

RPMI with Hepes/Pen strep/FBS -15 mL

  

EDTA whole blood

Ambient

Body fluid

Refrigerated

Bone marrow

Ambient

Spinal fluid

Refrigerated

Tissue

Refrigerated

  
  • Improper label (unlabeled or mislabeled)
  • Wrong container (anticoagulant or solution)
    • Tissues submitted in saline or B+ fixative are not acceptable and will be rejcted
  • Improper blood/anticoagulant ratio
  • Delay in transport
  • Improper storage
  • Inappropriate timing of collection
  • Interfering substances
  • Leaking container
  
AHL - Flow Cytometry: F
  
Mo - Fr
  
2 days
  

Flow cytometry

  

Tubes and Markers:

Tubes:
M1, M2, M3, M4, M5

Markers:CD2, CD3(cy), CD5, CD7, CD10, CD11b, CD13, CD14, CD15, CD16, CD19, CD22(cy), CD33, CD34, CD36, CD38, CD45, CD45RA, CD56, CD64, CD65, CD71, CD79a(cy), CD117, CD123, CD235a, CD300e, CD371, HLA-DR, MPO(cy), TdT(n)

  
88184
88185 x 30
  
06/12/2017
  
10/28/2022
  
01/09/2024