This assay is performed on the Roche analyzer platform beginnning 1/3/2023.
This assay is used as an aid in the diagnosis of individuals suspected of having congestive heart failure. The test is further indicated for the risk stratification of patients with acute coronary syndrome and congestive heart failure. The test may also serve as an aid in the assessment of increased risk of cardiovascular events and mortality in patients at risk for heart failure who have stable coronary artery disease.
Immediately following collection, mix sample thoroughly by gently inverting 8 - 10
Spin
Lt green plasma separator (PST)
Immediately following collection, mix sample thoroughly by gently inverting 8 - 10 times
Gold
Lavender
Gold serum separator (SST) tube
or
Refrigerated (preferred) – 6 days
Ambient - 3 days
Frozen – 24 months
Electrochemiluminescence immunoassay (ECLIA)
<75 yrs: <125 pg/mL
>76 yrs: <450 pg/mL